MODE SELECTION
If the P.E. input is configured to stop the gate during opening or
closing, then the gate can auto-close from a midway position. This
feature is implemented so that once a vehicle has entered the gate-
way and broken the P.E. beam, the gate will stop. When the P.E.
beam is cleared the gate will auto-close from the stopped position.
This results in the gate not having to fully open and thus reducing
the time unwarranted access through the gate is possible. The
factory set delay time of 1 second is adjustable, see section “P.E.
TRIGGERED AUTO-CLOSE DELAY TIME” below.
MIXING AUTO-CLOSE MODES
The PEDESTRIAN AUTO-CLS mode and the STANDARD
AUTO-CLS mode do not affect each other as one operates during
standard operation and the other during pedestrian access.
However it is possible to have P.E. triggered pedestrian auto-close
by selecting both the PEDESTRIAN AUTO-CLS and P.E.
TRIGGERED AUTO-CLS modes. In this case the gate would
partly open for pedestrian access and then either the P.E.
TRIGGERED AUTO-CLS would cause the gate to auto-close
when a pedestrian walks through and activates the P.E beam or, if
no one walked through the PEDESTRIAN AUTO-CLS would
close the gate. This way the gate is only kept open long enough
for a person to walk through, but with the backup that if no one
walks through the gate will still close. The same concept can be
used with standard operation by selecting both the STANDARD
AUTO-CLS and the P.E. TRIGGERED AUTO-CLS modes. That
is, the gate would only stay open long enough for the vehicle to
pass through but would still auto-close if no vehicle enters.
Note: P.E. TRIGGERED AUTO-CLS will not operate during
pedestrian access unless the PEDESTRIAN AUTO-CLS mode is
also selected.
16
MODE SETTING ADJUSTMENT
This section describes how to adjust several parameters via the
control boards buttons and dials. Other adjustments can be
performed by use of the advanced technicians Control Board
Instruction Manual and Programmer. Contact your local ATA
dealer for a copy.
SYNCHRONISING DELAY TIME
The synchronising delay time is adjusted using the 'SYNC delay
timer' button. The synchronising delay time is adjustable in 0.1
second steps. The factory set default is 2 seconds.
STANDARD AUTO-CLOSE DELAY TIME
The standard auto-close delay time is adjusted using the 'STD
auto-close' button. Delay time is adjustable in 1 second steps. The
factory set default is 30 seconds.
PEDESTRIAN ACCESS AUTO-CLOSE DELAY TIME
The pedestrian auto-close delay time is adjusted using the 'PED
auto-close' button. Delay time is adjustable in 1 second steps. The
factory set default is 15 seconds.
P.E. TRIGGERED AUTO-CLOSE DELAY TIME
The P.E. triggered auto-close delay time is adjusted using the
'P.E. auto-close' button. Delay time is adjustable in 1 second steps.
The factory set default is “off”.
PEDESTRIAN ACCESS CYCLE TIME
The pedestrian access cycle time sets how far gate leaf 1 opens for
pedestrian access.
1. Drive the gate to the closed position using the OSC button or
another control input.
2. Press and hold the 'PED cycle timer' button. The gate leaf
driven by motor 1 will start to open.
3. When the gate leaf has reached a position suitable for
pedestrian access, release the button.
4. The pedestrian access drive timer has now been set. Either
press the OSC button and exit the time set mode or continue
setting one of the synchronising delay or auto-close times.
SLOW MOTOR SPEED
IMPORTANT: Please make sure that the gate(s) are in the open
position before proceeding with steps 1 to 5 below.
The speed the motor slows down towards the end of a cycle can
be adjusted using the following procedure. The factory set
default slow speed is set to “ 3”
1. Note the current maximum speed selected by the speed
selection dial.
2. Using the speed selection dial select the desired slow speed.
3. Press and hold the 'RESET' button and count five (5) flashes of
the OPEN status led.
4. Release button.
5. Place the speed selection dial back to the desired maximum
speed .
ADJUSTING AUTO-CLOSE AND SYNC DELAY TIMES
1. Press and hold the required button for the desired time.
2. Release button.
3. Press the OSC button to exit the time setting mode or restart
from step 1 to set another time.
Notes:
a) The time setting mode is indicated by both the OPEN and
CLOSE status LED's being off.
b) Each flash of the OPN led represents 1 second.
c) When a button is first pressed, the CLOSE status LED turns
on. The time delay is set to zero when the CLOSE LED turns
off and then increases for as long as the button is held.